Medovia Medical Medovia Medical

Simple Cheap Portable Medical Ventilator Price (PA-500 Model)

Still deciding? Get samples of $ !
Request Sample

Product Description

i

Basic Specifications

Model NO.PA-500
Ventilation ModeA/C, IPPV, SIPPV, IMV, SIMV, Standby, Manual
Tidal Volume50-1200ml
Respiratory Rate6-60bpm
(I:E) Ratio1:1.5-1:3.0
PEEP0-10CMH2o
AnesthesiaClosed Circuit
GroupAdult & Child
LCD DisplayLED Display Screen
SourceOxygen and Air

PA-500 Simple Cheap Portable Medical Ventilator

PA-500 Medical Ventilator

Common Features

Pneumatically driven electrically controlled ventilator for emergency clinical resuscitation and respiratory therapy.
High visibility, wide angle LED alphanumeric data display with tactile analog parameter controls.
Equipped with high precession infrared turbine pressure and flow sensors.
Automatic conversion to standby mode during AC power outages for continuous safety.
Nonhazardous environmentally friendly frame with automated self-checking and self-calibrating sensors.
Comprehensive audible and visual alarms for tidal volume, airway pressure, and power/oxygen failure.
Integrated 9-level adjustable humidifier for patient comfort.

Technical Specifications

ModelPA-500
DisplayLED
Ventilation ModeA/C, IPPV, SIPPV, IMV, SIMV, MANUAL
Minute Volume≥ 18L
Back-up Power SupplyAt least 4 hours
Tidal VolumeAdjustable: 50-1500ml, Display: 0-2000ml
Output Oxygen Concentration< 50%
Respiratory Rate6-60bpm
Pressure Limit1-6kPa
PEEP1-10cmH2O
SIMV Rate1-12bpm
Inspiratory Pressure Trigger-4 to 10cmH2O
SIGH1 sigh breath in every 80-120 breaths
Gas Supply Requirement280~600 kPa medical grade oxygen
PA-500 Details
PA-500 Components
?

Frequently Asked Questions

What ventilation modes does the PA-500 support?
The PA-500 supports multiple modes including A/C, IPPV, SIPPV, IMV, SIMV, and Manual mode, making it versatile for various clinical needs.
Is this ventilator suitable for both adults and children?
Yes, the PA-500 is designed for both adult and pediatric patients, with an adjustable tidal volume range starting from 50ml.
How long can the battery last during a power failure?
The device is equipped with a back-up power supply that provides at least 4 hours of operation during AC power outages.
What kind of gas supply is required for operation?
It requires medical grade oxygen with a pressure range between 280 and 600 kPa.
Does the PA-500 include a humidification system?
Yes, it features a 9-level adjustable humidifier to ensure the delivered air is properly conditioned for the patient.
What safety alarms are integrated into the system?
The ventilator includes audible and visual alarms for tidal volume, airway pressure, power failure, and oxygen supply failure.